GENERAL ELECTRIC CO -- RTV109 -- 8040-01-082-1521
===================== Product Identification =====================
Product ID:RTV109
MSDS Date:07/15/1988
FSC:8040
NIIN:01-082-1521
=== Responsible Party ===
Company Name:GENERAL ELECTRIC CO
Address:260 HUDSON RIVER RD
City:WATERFORD
State:NY
ZIP:12188
Country:US
Info Phone Num:518-237-3330
Emergency Phone Num:518-237-3330
Preparer's Name:DA POLISINELLI
CAGE:01139
=== Contractor Identification ===
Company Name:GENERAL ELECTRIC CO, SILICONE PRODUCTS BUSINESS DEPT
Address:260 HUDSON RIVER RD
Box:City:WATERFORD
State:NY
ZIP:12188
Country:US
Phone:518-237-3330/800-332-3390
CAGE:01139
============= Composition/Information on Ingredients =============
Ingred Name:SILANE, METHYLTRIACETOXY-; (METHYLTRIACETOXYSILANE)
CAS:4253-34-3
RTECS #:VV4500000
Fraction by Wt: 1-5%
OSHA PEL:N/K
ACGIH TLV:N/K
===================== Hazards Identification =====================
LD50 LC50 Mixture:LD50: (ORAL, RAT) 2060 MG/KG
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INGESTION: NONE KNOWN. SKIN:
UNCURED PRODUCT CONTACT WILL IRRITATE LIPS, GUMS AND TONGUE; MAY
IRRITATE THE SKIN. INHALATION: APPLIES ONLY IN UNCURED STATE. MAY
CAUSE MILD RESPIRATORY IRRITATION . EYES: UNCURED PRODUCT CONTACT
IRRITATES EYES. OTHER: ACETIC ACID RELEASED DURING CURING. CHRONIC:
NONE KNOWN.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:RESPIRATORY, DERMAL AILMENTS.
APPLIES IN UNCURED STATE.
======================= First Aid Measures =======================
First Aid:INGEST: DO NOT INDUCE VOMITING. GIVE LARGE QTYS OF WATER TO
DRINK & GET MED ATTN. NEVER GIVE ANYTHING BY MOUTH TO AN UNCON
PERSON. SKIN: TO CLEAN FROM SKIN, REMOVE COMPLETELY W/DRY CLOTH OR
PAPER TOWE L, BEFORE WASHING W/DETERGENT & WATER. GET MED ATTN IF
IRRIT PERSISTS. INHAL: MOVE PERSON TO FRESH AIR. EYES: IMMED FLUSH
EYES W/PLENTY OF WATER FOR AT LEAST 15 MIN & GET MED ATTN IF IRRIT
PERSISTS.
===================== Fire Fighting Measures =====================
Flash Point Method:TOC
Flash Point:>400F,>204C
Extinguishing Media:ALL STANDARD FIREFIGHTING MEDIA.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NONE SPECIFIED BY MANUFACTURER.
================== Accidental Release Measures ==================
Spill Release Procedures:WIPE, SCRAPE OR SOAK UP IN AN INERT MATERIAL
AND PUT IN A CONTAINER FOR DISPOSAL. WEAR PROPER PROTECTIVE
EQUIPMENT AS SPECIFIED IN PROTECTIVE EQUIPMENT SECTION. WARN OTHER
WORKERS OF SPILL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID CONTACT WITH SKIN & EYES.
Other Precautions:CAUTION! REMOVE CONTACT LENSES BEFORE USING SEALANT.
DO NOT HANDLE LENSES UNTIL ALL SEALANT HAS BEEN CLEANED FROM
FINGERTIPS, NAILS & CUTICLES. RESIDUAL SEALANT MAY REMAIN ON
FINGERS FOR SEVERAL DAYS & TRANSFER TO LENSES & CAUSE (SUPDAT)
============= Exposure Controls/Personal Protection =============
Respiratory Protection:USE IN A WELL VENTILATED AREA. USE NIOSH/MSHA
APPROVED RESPIRATOR APPROPRIATE FOR EXPOSURE OF CONCERN .
Ventilation:USE ONLY IN WELL VENTILATED AREA. EXHAUST VENTILATION.
Protective Gloves:CLOTH GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:EYEWASH STATIONS.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
OTHER PREC: SEV EYE IRRIT. PROD RELS ACETIC ACID DURING APPLICATION &
CURING. USE MECH VENT TO STAY BELOW TLV OF 10 PPM ACETIC ACID.
UNCURED PROD CNTCT IRRIT EYES & MAY IRRIT SKIN. USE IN WELL VENT AR
EA TO PVNT IRRIT BY VAPS.
================== Physical/Chemical Properties ==================
Vapor Pres:NEG
Vapor Density:NEG
Spec Gravity:1.07 (H*2O=1)
Evaporation Rate & Reference:<1 (BUTYL ACETATE=1)
Solubility in Water:INSOLUBLE
Appearance and Odor:ALUMINUM COLOR PASTE; ACETIC ACID ODOR.
Percent Volatiles by Volume:<5
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NONE KNOWN.
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:SILICON DIOXIDE, ACETIC ACID.
==================== Disposal Considerations ====================
Waste Disposal Methods:DISPOSAL SHOULD BE MADE IN ACCORDANCE WITH
FEDERAL, STATE AND LOCAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.