FEDERAL-MOGUL CORP, TARGET PROD DIV. -- CARBON STEEL WIRE BRUSHES, CUP -- 5610-00F016224
=====================  Product Identification  =====================

Product ID:CARBON STEEL WIRE BRUSHES, CUP
MSDS Date:07/06/1988
FSC:5610
NIIN:00F016224
=== Responsible Party ===
Company Name:FEDERAL-MOGUL CORP, TARGET PROD DIV.
Address:4320 CLARY BOULEVARD
City:KANSAS CITY
State:MO
ZIP:64130
Info Phone Num:(816) 923-5040
Emergency Phone Num:(816) 923-5040
CAGE:9U240
=== Contractor Identification ===
Company Name:FEDERAL-MOGUL CORP., TARGET PRODUCTS DIVISION
Address:4320 CLARY BLVD.
Box:City:KANSAS CITY
State:MO
ZIP:64130
Phone:(816) 923-5040
CAGE:9U240

=============  Composition/Information on Ingredients  =============

Ingred Name:IRON
CAS:7439-89-6
RTECS #:NO4565500

Ingred Name:MANGANESE  (SARA III)
CAS:7439-96-5
RTECS #:OO9275000
Fraction by Wt: <1.25%
OSHA PEL:(C) 5 MG/M3 DUST
ACGIH TLV:5 MG/M3 DUST 9293

Ingred Name:TRACE ELEMENTS
Fraction by Wt: <2%

=====================  Hazards Identification  =====================

Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:SKIN/EYE/INHALATION/INGESTION:
    IRRITATION.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:SKIN/EYE/INHALATION/INGESTION: IRRITATION.

=======================  First Aid Measures  =======================

First Aid:EYES: FLUSH W/WATER. SKIN: WASH W/SOAP & WATER. INHALATION:
    REMOVE TO FRESH AIR. INGESTION: OBTAIN MEDICAL ATTENTION IN ALL
    CASES.

=====================  Fire Fighting Measures  =====================

Extinguishing Media:NO HAZARD; NOT COMBUSTIBLE IN AIR.

======================	Handling and Storage  ======================

Other Precautions:IN POWER BRUSHING OPERATIONS THE MATERIAL BEING
    REMOVED SUCH AS BURS/SCALE/DIRT/WELD SLAG WILL FLY OFF THE BRUSH
    W/CONSIDERABLE FORCE ALONG W/THE BRUSH FILAMENTS WHICH BREAK OFF
    DUE TO FATIGUE. THE PO TENTIAL FOR SERIOUS INJURY EXISTS.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:USE PROPERLY FITTED NIOSH APPROVED DUST FUME
    RESPIRATOR WHEN ENGINEERING CONTROLS ARE NOT SUFFICIENT TO LOWER
    EXPOSURE LEVELS