ENGLEHARD CORP -- GENERAL PURPOSE PASTE SOLDERING FLUX -- 3439-00N040196
===================== Product Identification =====================
Product ID:GENERAL PURPOSE PASTE SOLDERING FLUX
MSDS Date:08/25/1992
FSC:3439
NIIN:00N040196
=== Responsible Party ===
Company Name:ENGLEHARD CORP
Address:235 KILVERT ST
City:WARWICK
State:RI
ZIP:02886
Country:US
Info Phone Num:401-739-9550
Emergency Phone Num:800-424-9300 (CHEMTREC)
CAGE:HO905
=== Contractor Identification ===
Company Name:ENGELHARD CORP
Address:235 KILVERT ST
Box:City:WARWICK
State:RI
ZIP:02886
Country:US
Phone:401-739-9550
CAGE:86337
Company Name:ENGLEHARD CORP
Address:ROUTE 152
Box:City:PLAINVILLE
State:MA
ZIP:02762
Country:US
Phone:508-695-7811
CAGE:HO905
============= Composition/Information on Ingredients =============
Ingred Name:ING 3: REGULATORY AUTHORITIES. NOTE: CHEM ADDNS, PROCESSING
OR OTHERWISE ALTERING THIS MATL MAY MAKE WASTE (ING 5)
RTECS #:9999999ZZ
Ingred Name:ING 4: MANAGEMENT INFO GIVEN INCOMPLETE, INACCURATE OR
OTHERWISE INAPPROP. AS LOCAL REGS MAY VARY, ALL WASTE (ING 6)
RTECS #:9999999ZZ
Ingred Name:ING 5: MUST BE DISPOSED/RECYCLED/RECLAIMED I/A/W FED, STATE
& LOCAL ENVIRONMENTAL CONTROL REGULATIONS.
RTECS #:9999999ZZ
Ingred Name:PETROLATUM
CAS:8009-03-8
RTECS #:SE6780000
Fraction by Wt: 70.8%
OSHA PEL:N/K
ACGIH TLV:N/K
Ingred Name:ZINC CHLORIDE (SARA 313) (CERCLA)
CAS:7646-85-7
RTECS #:ZH1400000
Fraction by Wt: 25.3%
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3; 2 STEL FUME
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS
Ingred Name:WASTE DISP METH: RECLAMATION REQS WILL VARY BY LOCATION &
TYPE OF DISP SELECTED. CONSULT W/STATE & LOCAL (ING 4)
RTECS #:9999999ZZ
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYE CONTACT CAUSES IRRITATION & MAY
CAUSE BURNS. SKIN CONTACT CAUSES IRRITATION & MAY CAUSE BURNS.
SENSITIZATION & ALLERGIC REACTIONS ARE POSSIBLE. INHALATION OF
MISTS IS SEVERELY IRRITATING TO RESPIR ATORY TRACT & CAN CAUSE
BURNING SENSATION, COUGHING, WHEEZING, BRONCHITIS, PNEUMONITIS &
PULMONARY (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: EDEMA. MAY CAUSE ALLERGIC RESPIRATORY
REACTIONS. INGESTION IS HARMFUL. CAN CAUSE SEVERE IRRITATION &
POSSIBLE BURNS TO MUCOUS MEMBRANES. MAY CAUSE SEVERE ABDOMINAL
PAIN, VOMITING & DIARRHEA. CHRONIC: PROLONGED/REPEATED
OVEREXPOSURE MAY CAUSE LUNG DAMAGE. OVEREXPOSURE MAY CAUSE DELAYED
KIDNEY INJURY.
Medical Cond Aggravated by Exposure:MAY AGGRAVATE EXISTING RESPIRATORY
AND/OR SKIN AILMENTS.
======================= First Aid Measures =======================
First Aid:EYES:IMMED FLUSH W/PLENTY OF WATER FOR @ LEAST 30 MIN. HOLD
LIDS OPEN DURING FLUSHING W/WATER. CALL MD IMMED. SKIN: FLUSH
W/PLENTY OF WATER. IF IRRIT PERSISTS, CALL MD. INHAL:REMOVE TO
FRESH AIR. IF N OT BRTHG, GIVE ARTF RESP, PREF MOUTH-TO-MOUTH. IF
BRTHG IS DFCLT, GIVE OXYGEN. CALL MD. INGEST:DO NOT INDUCE VOMIT.
GIVE LG QTYS OF WATER. CALL MD IMMED. NEVER GIVE ANYTHING BY MOUTH
TO UNCON PERSON.
===================== Fire Fighting Measures =====================
Flash Point:>356F,>180C
Extinguishing Media:USE WATER, CARBON DIOXIDE OR FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:NOT A FIRE OR EXPLOSION HAZARD. HOWEVER,
TOXIC EMISSIONS ARE POSSIBLE IN A FIRE SITUATION.
================== Accidental Release Measures ==================
Spill Release Procedures:CONTAIN SPILL & SCOOP UP/VACUUM. NOTIFICATION
OF NRC (800-424-8801) MAY BE REQD. REFER TO EPA, DOT & APPLIC STATE
& LOC REGS FOR CURRENT RESPONSE INFO. IT IS RECOM THAT EACH USER
ESTABLISH SPILL PREVE NTION, CTL & COUNTERMEASURE PLAN (SPCC).
(SUPDAT)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN TIGHTLY CLOSED CONTAINER.
STORE IN A COOL, DRY LOCATION AWAY FROM INCOMPATIBLE MATERIALS.
Other Precautions:KEEP AWAY FROM FOOD AND FEED PRODUCTS. WASH
THOROUGHLY AFTER HANDLING. AVOID CONTACT W/ANY DUSTS, MISTS OR
FUMES RESULTING FROM USE OF THIS PROCUT. WASH CONTAMINATED CLOTHING
BEFORE REUSE. HARMFUL IF SWALLOWED.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:A NIOSH/MSHA APPROVED RESPIRATOR AS NECESSARY.
Ventilation:GENERAL; LOCAL EXHAUST VENT AS NECESSARY TO CONTROL ANY AIR
CONTAMINANTS TO W/IN THEIR TLVS DURING USE OF THIS PRODUCT.
Protective Gloves:RUBBER OR NEOPRENE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:BODY PROTECTION AS NECESSARY TO PVNT SKIN
CONTACT. PROVIDE SAFETY SHOWER & EYE WASH CLOSE TO WHERE MATL IS
BEING USED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SPILL PROC: SUCH PLAN SHOULD INCL PROCS APPLIC TO PROPER STORAGE, CTL &
CLEAN-UP OF SPILLS, INCL REUSE/DISP AS APPROP. NOTE:IN EVENT OF
ACCIDENTAL RELS OF MATL, FOLLOW SPILL PROCS. ADDNLY PROPER EXPOS
CTLS & PERSONAL PROT EQUIP SHOULD BE USED & DISP OF MATL SHOULD BE
I/A/W DISP REGS.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:165F,74C
Melt/Freeze Pt:M.P/F.P Text:216F,102C
Vapor Pres:<10 @ 20C
Spec Gravity:1.4 (H*2O=1)
pH:1.8
Solubility in Water:INSOLUBLE
Appearance and Odor:AMBER JELLY; ODORLESS.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ALKALIES, OXIDIZERS.
Stability Condition to Avoid:NONE EXPECTED.
Hazardous Decomposition Products:HYDROGEN CHLORIDE, ZINC OXIDE AND
OXIDES OF CARBON.
==================== Disposal Considerations ====================
Waste Disposal Methods:EPA WASTE #:D002. CORR MATL. PROD MAY BE HAZ
WASTE UNDER EPA WASTE REGS. BEFORE DISP, PROD/MIX CONTAINING PROD
SHOULD BE TESTED FOR TOX CHARACTS (TC) UNDER CURRENT EPA HAZ WASTE
REGS TCLP TESTING PROC S, 40 CFR 261 ET SEQ. DISPOSAL/RECYCLING/
(ING 3)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.