RICHARD KLINGER INC -- COMPRESSION PACKING STYLE 49/490 -- 5330-00N025756
===================== Product Identification =====================
Product ID:COMPRESSION PACKING STYLE 49/490
MSDS Date:05/26/1989
FSC:5330
NIIN:00N025756
=== Responsible Party ===
Company Name:RICHARD KLINGER INC
Address:2350 CAMPBELL RD
City:SIDNEY
State:OH
ZIP:45365
Country:US
Info Phone Num:513-498-1181
Emergency Phone Num:513-498-1181
Preparer's Name:PHIL CORNOCK
CAGE:K0076
=== Contractor Identification ===
Company Name:KLINGER RICHARD INC
Address:2350 CAMPBELL RD
Box:City:SIDNEY
State:OH
ZIP:45365-9501
Country:US
Phone:937-498-1181
CAGE:9U500
Company Name:RICHARD KLINGER LTD
Box:City:SIDCUP KENT DA14 5AG UNITED KINGDOM
Phone:01-300-7777
CAGE:K0076
============= Composition/Information on Ingredients =============
Ingred Name:TETRAFLUORO ETHYLENE POLYMER; (TEFLON)
CAS:116-14-3
RTECS #:KX4025000
Ingred Name:GRAPHITE
CAS:7782-42-5
RTECS #:MD9659600
OSHA PEL:15 MPPCF RDUST
ACGIH TLV:2 MG/M3 RDUST; 9293
===================== Hazards Identification =====================
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:(ACUTE & CHRONIC)PTFE WILL NOT SUPPORT
COMBUST BUT AT TEMPS >200C WILL BEGIN TO DEGRADE W/EVOLUTION OF
VAPS WHICH MAY BE HARMFUL IF ALLOWED TO CONC IN THE WORKPLACE.
EXPSD WORKERS MAY EXHIBIT FLU-LIKE SYMP WHICH NORMALLY WILL PASS
OFF WITHIN 36-48 HRS FOLLOWING EXPOS. OBSERVATIONS INDICATE SUCH
ATTACKS(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: DO NOT HAVE ANY LASTING EFFECTS NOR
THAT THE EFFECTS ARE CUMULATIVE. THEIR OCCURENCE INDICATES
VENTILATION IS INADEQUATE AND SHOULD BE IMPROVED.
Medical Cond Aggravated by Exposure:NONE KNOWN.
======================= First Aid Measures =======================
First Aid:WORKERS EXPSD TO THERMAL DEGRADATION PRODS SHOULD BE REFERRED
IMMED TO PHYSICIAN FOR TREATMENT OF IRRIT. SKIN: WORKERS SHOULD BE
REQ TO WASH EXPSD SKIN SURFACES W/SOAP & WATER AFTER HNDLG. INGEST:
CAL L MD IMMED . INHAL: REMOVE TO FRESH AIR. SUPPORT BREATHING
(GIVE O*2/ARTIFICIAL RESPIRATION) . EYES: IMMED FLUSH W/POTABLE
WATER FOR A MINIMUM OF 15 MIN, SEEK ASST FROM MD .
===================== Fire Fighting Measures =====================
Flash Point:DOES NOT FLASH
Extinguishing Media:MATL WILL NOT SUPPORT COMBUST. USE MEDIA SUITABLE
FOR SURROUNDING FIRE .
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:POLYTETRA-FLUORETHYLENE POLYMER (PTFE)
WILL NOT SUPPORT COMBUST BUT AT TEMPS >200C WILL BEGIN TO DEGRADE
W/EVOLUTION OF VAPS WHICH MAY BE HARMFUL IF (SUPP DATA)
================== Accidental Release Measures ==================
Spill Release Procedures:VACUUM ANY DUST RELEASED.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:USE OSHA APPROVED DUST MASK IF
MECHANICAL PROCESSING RESULTS IN EXCESSIVE DUST RELEASE.
Other Precautions:CARE SHOULD BE TAKEN THAT FLY OR DUST FROM PTFE IS
NOT ALLOWED TO CONTAMINATE TOBACCO OR OTHER SMOKING MATERIALS.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:IF OVEREXPOSED TO PTFE THERMAL DEGRADATION
PRODUCTS, USE NIOSH/MSHA APPROVED HIGH EFFICIENCY FILTER
RESPIRATOR.
Ventilation:MECHANICAL: RECOMMENDED. LOCAL EXHAUST: AT ELEVATED
TEMPERATURES.
Protective Gloves:PROTECTIVE GLOVES RECOMMENDED.
Eye Protection:CHEMICAL WORKERS GOGGLES .
Other Protective Equipment:NOT NORMALLY REQUIRED.
Work Hygienic Practices:EXPOS TO ANY INHALABLE MATL SHOULD BE MINIMIZED
BY ADEQUATE, EFFECTIVE CONTAINMENT & PERSONAL CLEANLINESS.
Supplemental Safety and Health
EXPLO HAZ: ALLOWED TO CONCENTRATE IN THE WORKPLACE. IN A FIRE, HYDROGEN
FLUORIDE MAY BE EVOLVED.
================== Physical/Chemical Properties ==================
HCC:N1
Spec Gravity:1.70
Solubility in Water:INSOLUBLE
Appearance and Odor:GRAYISH BLACK BRAIDED COMPRESSION PACKING, SLIPPERY
TO TOUCH, NO ODOR.
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
NOT RECOMMENDED FOR MOLTEN ALKALI METALS, ELEMENTAL FLUORINE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:FLUORIDE
==================== Disposal Considerations ====================
Waste Disposal Methods:APPROVED LANDFILL IN ACCORDANCE WITH FEDERAL,
STATE, OR LOCAL LAWS AND ORDINANCES.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.