CALGON VESTAL LAB DIV OF CALGON CORP -- TY-ION C-81M -- 6850-00F001052
===================== Product Identification =====================
Product ID:TY-ION C-81M
MSDS Date:10/14/1987
FSC:6850
NIIN:00F001052
=== Responsible Party ===
Company Name:CALGON VESTAL LAB DIV OF CALGON CORP
Address:5035 MANCHESTER AVE
City:ST LOUIS
State:MO
ZIP:63110
Country:US
Info Phone Num:315-535-1810
Emergency Phone Num:314-535-1395
Preparer's Name:R C JENTE
CAGE:21667
=== Contractor Identification ===
Company Name:CONVATEC, BRISTOL-MEYERS SQUIBB CO
Address:7501 PAGE
Box:147
City:ST. LOUIS
State:MO
ZIP:63166-1096
Country:US
Phone:314-535-1810 (DAY)
CAGE:21667
============= Composition/Information on Ingredients =============
Ingred Name:NON HAZARDOUS INGREDIENTS
===================== Hazards Identification =====================
LD50 LC50 Mixture:ORAL LD50 (RATS): >5000 MG/KG
Routes of Entry: Inhalation:NO Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:DISPERSANTS IN PRODUCT MAY BE MILDLY
IRRITATING TO EYES & SKIN.
Explanation of Carcinogenicity:NONE
Effects of Overexposure:DISPERSANTS IN PRODUCT MAY BE MILDLY IRRITATING
TO EYES & SKIN.
======================= First Aid Measures =======================
First Aid:EYES: FLUSH W/FLOWING WATER FOR 15 MINS. SKIN: WASH
THOROUGHLY W/SOAP & WATER. INHALATION: REMOVE TO FRESH AIR.
INGESTION: GIVE LARGE AMOUNTS OF WATER. OBTAIN MEDICAL ATTENTION IN
ALL CASES.
===================== Fire Fighting Measures =====================
Extinguishing Media:WATER, CO2, FOAM, DRY CHEMICAL
================== Accidental Release Measures ==================
Spill Release Procedures:SMALL: MAY BE MOPPED UP/FLUSHED TO DRAIN
W/WATER.
====================== Handling and Storage ======================
Handling and Storage Precautions:AVOID FREEZING. IF FREEZING OCCURS,
THAW AND AGITATE UNTIL HOMOGENEOUS.
============= Exposure Controls/Personal Protection =============
Ventilation:NORMAL ROOM
Protective Gloves:RUBBER
Eye Protection:SAFETY GLASSES, GOGGLES
Other Protective Equipment:PROTECTIVE APRON.
Supplemental Safety and Health
WASTE DISPOSAL CONT'D: DISPOSE OF IAW/FEDERAL, STATE & LOCAL
REGULATIONS.
================== Physical/Chemical Properties ==================
Boiling Pt:B.P. Text:210F
Melt/Freeze Pt:M.P/F.P Text:20F
Spec Gravity:1.024
pH:8.1
Solubility in Water:COMPLETE
Appearance and Odor:AMBER MOBILE LIQUID W/MILD ODOR.
Percent Volatiles by Volume:90/WT
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
ANIONIC MATERIALS, STRONG OXIDIZERS
Stability Condition to Avoid:FREEZING
Hazardous Decomposition Products:CO, CO2 & NITROGEN OXIDES
==================== Disposal Considerations ====================
Waste Disposal Methods:TOXIC TO FISH. PRODUCT/TREATED EFFLUENT
INCLUDING TOWER BLEED SHOULD BE DISCHARGED TO A DRAIN SERVED BY A
SANITARY SEWER. DON'T DISCHARGE TOWER EFFLUENT/RINSINGS FROM EMPTY
CONTAINERS WHERE IT WILL DR AIN IN LAKES/STREAMS/PONDS/PUBLIC
WATERS. (SUPP)
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.