DU PONT FLUOROPRODUCTS -- "SUVA" HP81 (R402B) -- 6830-01-391-3103
===================== Product Identification =====================
Product ID:"SUVA" HP81 (R402B)
MSDS Date:03/24/1999
FSC:6830
NIIN:01-391-3103
Status Code:A
=== Responsible Party ===
Company Name:DU PONT FLUOROPRODUCTS
Address:1007 MARKET STREET
City:WILMINGTON
State:DE
ZIP:19898
Country:US
Info Phone Num:1-800-441-7515
Emergency Phone Num:800-441-3637/800-424-9300(CHEMTREC)
Resp. Party Other MSDS Num.:6000FR
Chemtrec Ind/Phone:(800)424-9300
CAGE:2S827
=== Contractor Identification ===
Company Name:BAKER DISTRIBUTING CO NO 398
Address:2351 BUTTON GWINNET DR
Box:City:ATLANTA
State:GA
ZIP:30340
Country:US
Phone:770-441-1120
Contract Num:SP0450-01-M-D200
CAGE:7R667
Company Name:DU PONT FLUOROPRODUCTS
Address:1007 MARKET STREET
Box:City:WILMINGTON
State:DE
ZIP:19898
Country:US
Phone:1-800-441-7515
CAGE:2S827
============= Composition/Information on Ingredients =============
Ingred Name:ETHANE, PENTAFLUORO- (HFC-125)
CAS:354-33-6
= Wt:38.
Other REC Limits:NONE RECOMMENDED
Ingred Name:METHANE, CHLORODIFLUORO- (HFC-22)
CAS:75-45-6
RTECS #:PA6390000
= Wt:60.
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1000 PPM
ACGIH TLV:1000 PPM; 9596
Ozone Depleting Chemical:2
Ingred Name:PROPANE
CAS:74-98-6
RTECS #:TX2275000
= Wt:2.
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1000 PPM
ACGIH TLV:ASPHYXIANT; 9596
===================== Hazards Identification =====================
LD50 LC50 Mixture:ORAL (RAT): >230 PPM
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:INHALATION OF HIGH CONCENTRATIONS OF
VAPOR IS HARMFUL & MAY CAUSE HEART IRREGULARITIES, UNCONSCIOUSNESS,
OR DEATH. INTENTIONAL MISUSE OR DELIBERATE INHALATION MAY CAUSE
DEATH WITHOUT WARNING. VAPOR RE DUCES OXYGEN AVAILABLE FOR
BREATHING & IS HEAVIER THAN AIR. LIQUID CONTACT CAN CAUSE
FROSTBITE.
Explanation of Carcinogenicity:NONE OF THE COMPONENTS PRESENT IN THIS
MATERIAL AT CONCENTRATIONS EQUAL TO OR GREATER THAN 0.1% ARE LISTED
BY IARC, NTP, OSHA OR ACGIH AS A CARCINOGEN.
Effects of Overexposure:OVEREXPOSURE TO THE VAPORS BY INHALATION MAY
INCLUDE TEMPORARY NERVOUS SYSTEM DERPESSION WITH ANESTHETIC EFFECTS
SUCH AS DIZZINESS, HEADACHE, CONFUSION, INCOORDINATION, & LOSS OF
CONSCIOUSNESS. HIGHER EXPOSURES TO THE VAPORS MAY CAUSE TEMPORARY
ALTERATION OF THE HEART'S ELECTRICAL ACTIVITY WITH IRREGULAR PULSE,
PALPITATIONS, OR INADEQUATE. LIQUID CONTACT CAN CAUSE FROSTBITE.
Medical Cond Aggravated by Exposure:INDIVIDUALS WITH PRE-EXISTING
DISEASES OF THE CENTRAL NERVOUS OR CARDIOVASCULAR SYSTEM MAY HAVE
INCREASED SUSCEPTIBILITY TO THE TOXICITY OF INCREASED EXPOSURES.
======================= First Aid Measures =======================
First Aid:INHALATION: IF INHALED, IMMEDIATELY REMOVE TO FRESH AIR. KEEP
PERSON CALM, IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION. IF
BREATHING IS DIFFICULT, GIVE OXYGEN. CALL A PHYSICIAN. SKIN: FLUSH
WITH LU KEWARM WATER. DO NOT USE HOT WATER. IF FROSTBITE HAS
OCCURRED, CALL A PHYSICIAN. EYES: IMMEDIATELY FLUSH W/PLENTY OF
WATER FOR 15 MINUTES. CALL A PHYSICIAN. INGESTION: NOT A PROBABLE
ROUTE. HOWEVER, I N CASE OF ACCIDENTAL INGESTION, CALL A PHYSICIAN.
===================== Fire Fighting Measures =====================
Flash Point Method:TOC
Flash Point:WILL NOT BURN
Extinguishing Media:AS APPROPRIATE FOR COMBUSTIBLES IN AREA.
Fire Fighting Procedures:KEEP CYLINDERS COOL WITH WATER SPRAY OR FOG.
SCBA APPARATUS IS REQUIRED IF CYLINDERS RUPTURE AND CONTENTS ARE
RELEASED UNDER FIRE CONDITIONS. WATER RUNOFF SHOULD BE CONTAINED
AND NEUTRALIZED PRIOR TO RELEASE.
Unusual Fire/Explosion Hazard:CYLINDERS MAY RUPTURE UNDER FIRE
CONDITIONS. DECOMPOSITION MAY OCCUR. CONTACT OF WELDING OR
SOLDERING TORCH FLAME WITH HIGH CONCENTRATION OF REFRIGERANT CAN
RESULT IN VISIBLE CHANGES IN THE SIZE & COL OR OF TORCH FLAMES.
THIS FLAME EFFECT WILL ONLY OCCUR IN CONCENTRATIONS OF PRODUCT WELL
ABOVE THE RECOMMENDED EXPOSURE
================== Accidental Release Measures ==================
Spill Release Procedures:REMOVE OPEN FLAMES. USE SELF- CONTAINED
BREATHING APPARATUS (SCBA) FOR LARGE SPILLS OR RELEASES.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
====================== Handling and Storage ======================
Handling and Storage Precautions:STORE IN A CLEAN, DRY PLACE. DO NOT
HEAT ABOVE 52C (126F).
Other Precautions:AVOID BREATHING VAPORS OR MIST. AVOID LIQUID CONTACT
WITH EYES OR SKIN. USE WITH SUFFCIENT VENTILATION TO KEEP EMPLOYEE
EXPOSURE BELOW THE RECOMMENDED LIMITS. AVOID PROLONGED OR REPEATED
EXPOSURE. WAS H THOROUGHLY AFTER HANDLING.
============= Exposure Controls/Personal Protection =============
Respiratory Protection:UNDER NORMAL MANUFACTURING CONDITIONS, NO
RESPIRATORY PROTECTION IS REQUIRED WHEN USING THIS PRODUCT.
SELF-CONTAINED BREATHING APPARATUS IS REQUIRED IF LARGE RELEASE
OCCURS.
Ventilation:LOCAL EXHAUST IF LARGE AMOUNTS ARE RELEASED. MECHANICAL
VENTILATION SHOULD BE USED IN LOW/ENCLOSED PLACES.
Protective Gloves:IMPERVIOUS GLOVES SHOULD BE USED TO AVOID PROLONGED
OR REPEATED CONTACT.
Eye Protection:CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:NONE SPECIFIED BY MANUFACTURER.
Work Hygienic Practices:WASH CONTAMINATED CLOTHING BEFORE REUSE.
Supplemental Safety and Health
NOTE TO PHYSICIAN: THIS MATERIAL MAY MAKE THE HEART MORE SUSCEPTIBLE TO
ARRHYTHMIAS. CATECHOLAMINES SUCH AS ADRENALINE, AND OTHER COMPOUNDS
HAVING SIMILAR EFFECTS, SHOULD ONLY BE USED WITH SPECIAL CAU TION.
================== Physical/Chemical Properties ==================
HCC:G3
Boiling Pt:=-47.4C, -53.3F
Vapor Pres:179.6 PSIA AT 25C(77F)
Vapor Density:1.14
Spec Gravity:1.14
Evaporation Rate & Reference:>1(CC14=1)
Solubility in Water:NOT DETERMINED
Appearance and Odor:CLEAR, COLORLESS LIQUIDFIED GAS W/SLIGHT ETHEREAL
ODOR
Percent Volatiles by Volume:100%
================= Stability and Reactivity Data =================
Stability Indicator/Materials to Avoid:YES
INCOMPATIBLE WITH ALKALI OR ALKALINE EARTH METALS-POWDERED ALUMINUM,
ZINC, BERYLLIUM. ETC.
Stability Condition to Avoid:AVOID OPEN FLAMES AND HIGH TEMPERATURES.
Hazardous Decomposition Products:"SUVA" HP81 CAN BE DECOMPOSED BY HIGH
TEMPERATURES (OPEN FLAMES, GLOWING METAL SURFACES, ETC.) FORMING
HYDROCHLORIC & HYDROFLUORIC ACIDS & POSSIBLY CARBONYL HALIDES.
THESE MATERIALS ARE TOXIC?
Conditions to Avoid Polymerization:WILL NOT OCCUR.
=================== Toxicological Information ===================
Toxicological Information:ANIMAL DATA: THE BLEND IS UNTESTED. ETHANE,
PENTAFLUORO-: INHALATION 4 HOUR ALC: > 709,000 PPM IN RATS.
SINGLE, HIGH INHALATION EXPOSURES CAUSED LETHARGY, DECREASED
ACTIVITY, LABORED BREATHING AND WE IGHT LOSS. WEAK CARDIAC
SENSITIATION EFFECT, POTENTIALLY FATAL DISTURBANCE OF HEART RHYTHM
CAUSED BY HEIGHTENED SENSITIVITY TO EPINEPHRINE. METHAN,
CHLORODIFLUORO-: INHALATION 4 HOUR LC50: 220,000 PPM IN RATS. THIS
COMPOUND IS A SKIN IRRITANT A& SLIGHT EYE IRRITANT, BUT IS NOT A
SKIN SENSITIZER IN ANIMALS. EFFECTS FROM SINGLE HIGH EXPOSURES
INCLUDE CNS DEPRESSION, ANESTHESIA, RAPID BRETAHING, LUNG
CONGESTION.
===================== Ecological Information =====================
Ecological:ECOTOXICOLOGICAL INFORMATION: AQUATIC TOXICITY: HFC-22: 48
HOUR EC50 - DAPHNE MAGNA: 433 MG/L.
==================== Disposal Considerations ====================
Waste Disposal Methods:COMPLY WITH FEDERAL, STATE & LOCAL REGULATIONS.
RECLAIM BY DISTILLATION OR REMOVE TO A PERMITTED WASTE DISPOSAL
FACILITY.
=================== MSDS Transport Information ===================
Transport Information:DOT/IMO: PROPER SHIPPING NAME: LIQUIFIED GAS,
N.O.S. (CHLORODIFLUOROMETHANE AND PENTAFLUOROETHANE). HAZARD CLASS:
2.2. UN NO.: 3163. DOT/IMO LABEL: NONFLAMMABLE GAS. SHIPPING
CONTAINERS: TANK CARS, CY LINDERS, TON TANKS.
===================== Regulatory Information =====================
SARA Title III Information:SARA EXTREMELY HAZARDOUS SUBSTANCE: NO. SARA
TOXIC CHEMICAL: DISCLOSURE AS A TOXIC CHEMICAL IS REQUIRED UNDER
SECTION 313 OF TITLE III OF THE SUPERFUND AMENDMENTS AND
REAUTHORIZATION ACT OF 1986 AND 4 0 CFR PART 372. TITLE III HAZARD
CLASSIFICATIONS SECTIONS 311/312: ACUTE: YES; CHRONIC: NO; FIRE:
NO; REACTIVITY: NO; PRESSURE: YES.
Federal Regulatory Information:TSCA INVENTORY STATUS:
REPORTED/INCLUDED.
State Regulatory Information:NOT PROVIDED BY MANUFACTURER
======================= Other Information =======================
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.