GENERAL MOTORS CORPORATION-CENTRAL FOUNDRY DIV -- CAST IRON CASTINGS -- 2520-00-999-6465
=====================  Product Identification  =====================

Product ID:CAST IRON CASTINGS
MSDS Date:11/22/1985
FSC:2520
NIIN:00-999-6465
Kit Part:Y
=== Responsible Party ===
Company Name:GENERAL MOTORS CORPORATION-CENTRAL FOUNDRY DIV
Box:1629
City:SAGINAW
State:MI
ZIP:48605
Country:US
Info Phone Num:313-556-1597/6200
Emergency Phone Num:313-556-1597/6200
CAGE:1T998
=== Contractor Identification ===
Company Name:EXXON COMPANY, U.S.A.
Address:ROOM 2344
Box:2180
City:HOUSTON
State:TX
ZIP:77252-2180
Country:US
Phone:713-656-5949
CAGE:72447
Company Name:GENERAL MOTORS CORP, GM SERVICE PARTS OPNS
Address:6060 W BRISTOL RD
City:FLINT
State:MI
ZIP:48554
Country:US
Phone:313-635-5905
CAGE:1T998

=============  Composition/Information on Ingredients  =============

Ingred Name:PHOSPHOROUS (YELLOW)  (SARA III)
CAS:7723-14-0
RTECS #:TH3500000
Fraction by Wt: 0.20%
Other REC Limits:NOT KNOWN
OSHA PEL:0.1 MG/M3
ACGIH TLV:0.1 MG/M3
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:COPPER.OSHA PEL AND ACGIH TLV 1 MG(CU)/M3 FOR DUST AND
    MIST.  (SARA III)
CAS:7440-50-8
RTECS #:GL5325000
Fraction by Wt: <0.40%
Other REC Limits:NOT KNOWN
OSHA PEL:0.1MG/M3 FUME
ACGIH TLV:0.2MG/M3 FUME
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

Ingred Name:CHROMIUM  (SARA III)
CAS:7440-47-3
RTECS #:GB4200000
Fraction by Wt: <0.60%
Other REC Limits:NOT KNOWN
OSHA PEL:1 MG(CR)/M3
ACGIH TLV:0.5 MG(CR)/M3
EPA Rpt Qty:1 LB
DOT Rpt Qty:1 LB

Ingred Name:MANGANESE.OSHA PEL IS FOR MANGANESE COMPOUNDS.(SARA III)
CAS:7439-96-5
RTECS #:OO9275000
Fraction by Wt: <1.2%
Other REC Limits:NOT KNOWN
OSHA PEL:(C) 5 MG/M3 DUST
ACGIH TLV:5 MG/M3 DUST 9293

Ingred Name:IRON.OSHA PEL FOR IRON OXIDE DUST & FUME TOTAL
    PARTICULATE.ACGIH TLV FOR IRON OXIDE FUME.
CAS:7439-89-6
RTECS #:NO4565500
Fraction by Wt: 91-96%
Other REC Limits:NOT KNOWN
OSHA PEL:10 MG(FE)/M3
ACGIH TLV:5 MG(FE)/M3 FUME

Ingred Name:MAGNESIUM.OSHA PEL 5 MG/M3 RESPIRABLE FRACTION FOR MG OXIDE
    FUME.ACGIH TLV FOR MG OXIDE FUME.
CAS:7439-95-4
RTECS #:OM2100000
Fraction by Wt: 0.07%
Other REC Limits:NOT KNOWN
OSHA PEL:10 MG/M3 TOTAL DUST
ACGIH TLV:10 MG/M3

Ingred Name:SILICON.OSHA PEL 5 MG/M3 RESPIRABLE FRACTION.ACGIH TLV FOR
    TOTAL DUST CONTAINING NO ASBESTOS & <1% CRYSTALLINE SILICA.
CAS:7440-21-3
RTECS #:VW0400000
Fraction by Wt: 1.0-2.7%
Other REC Limits:NOT KNOWN
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:10 MG/M3 TDUST; 9293

Ingred Name:CARBON.OSHA PELS FOR SYNTHETIC GRAPHITE.OSHA PEL 5 MG/M3
    RESP FRACTION.ACGIH TLV FOR GRAPHITE (ALL FORMS EXCEPT FIBERS).
CAS:7440-44-0
RTECS #:FF5250100
Fraction by Wt: 2.0-3.9%
Other REC Limits:NOT KNOWN
OSHA PEL:15 MG/M3 TDUST
ACGIH TLV:2 MG/M3 TDUST; 9293

Ingred Name:SULFUR
CAS:7704-34-9
RTECS #:WS4250000
Fraction by Wt: <0.15%
Other REC Limits:NOT KNOWN
OSHA PEL:NOT KNOWN
ACGIH TLV:NOT KNOWN

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NOT KNOWN
Routes of Entry: Inhalation:YES  Skin:NO  Ingestion:NO
Reports of Carcinogenicity:NTP:YES    IARC:NO	 OSHA:NO
Health Hazards Acute and Chronic:SEE SIGNS AND SYMPTOMS OF
    OVEREXPOSURE.
Explanation of Carcinogenicity:CHROMIUM & CERTAIN CHROMIUM
    COMPOUNDS:KNOWN HUMAN CARCINOGEN (NTP,1991).
Effects of Overexposure:DATA SUGGEST THAT NO OVEREXPOSURE TO CASTING
    DECOMPOSITION MATERIALS OCCUR UNDER NORMAL CONDITIONS OF
    USE.WELDING/GRINDING ON CASTINGS:CONDUCT AIR SAMPLING TO CONFIRM
    CONTROL OF DUST/FUMES BELOW APPLI CABLE LIMITS.
Medical Cond Aggravated by Exposure:NOT KNOWN

=======================  First Aid Measures  =======================

First Aid:EYES:FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
    MINUTES .

=====================  Fire Fighting Measures  =====================

Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS (SCBA)
    AND FULL TURNOUT GEAR .

==================  Accidental Release Measures  ==================

Neutralizing Agent:NOT KNOWN

======================	Handling and Storage  ======================

Other Precautions:CONTROL DUST/FUMES BELOW APPLICABLE LIMITS DURING
    WELDING/GRINDING.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF DUST/FUMES ARE GENERATED ABOVE THE PEL,USE A
    NIOSH APPROVED DUST/FUME RESPIRATOR.
Ventilation:LOCAL EXHAUST RECOMMENDED FOR WELDING OR GRINDING.
Protective Gloves:LEATHER
Eye Protection:SAFETY GOGGLES WITH SIDE SHIELDS.
Other Protective Equipment:NONE
Work Hygienic Practices:NOT KNOWN
Supplemental Safety and Health
CONTRACT #:DAA307-87-Y-1838,THIS ITEM PART OF DRIVESHAFT ASSEMBLY.%
    SOLID BY WEIGHT:100.

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:NOT KNOWN
Melt/Freeze Pt:M.P/F.P Text:2050F,1121C
Decomp Temp:Decomp Text:NOT KNOWN
Spec Gravity:7.2 (WATER=1)
Appearance and Odor:SOLID METALLIC CASTING.
Percent Volatiles by Volume:0

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE
Stability Condition to Avoid:NONE
Hazardous Decomposition Products:NONE

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
    FEDERAL,STATE,AND LOCAL REGULATIONS.COORDINATE WITH SUPPORTING
    INSTALLATION AND/OR MACOM ENVIRONMENTAL OFFICE PRIOR TO DISPOSAL .

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.