SENTINEL CHEMICAL CO INC -- 747 MASTIC REMOVER -- 6850-00N036697
=====================  Product Identification  =====================

Product ID:747 MASTIC REMOVER
MSDS Date:01/01/1993
FSC:6850
NIIN:00N036697
=== Responsible Party ===
Company Name:SENTINEL CHEMICAL CO INC
Address:7714 BEECH ST NE
City:MINNEAPOLIS
State:MN
ZIP:55432
Country:US
Info Phone Num:612-571-0630
Emergency Phone Num:800-228-5635
CAGE:SENTI
=== Contractor Identification ===
Company Name:SENTINEL CHEMICAL CO INC
Address:7714 BEECH ST NE
City:MINNEAPOLIS
State:MN
ZIP:55432
Country:US
Phone:612-571-0630
CAGE:SENTI

=============  Composition/Information on Ingredients  =============

Ingred Name:VENT: SYSTEMS MAY BE REQUIRED. WHERE EXPLOSIVE MIXTURES MAY
    BE PRESENT, SYSTEMS SAFE FOR SUCH LOCATIONS SHOULD BE USED.
RTECS #:9999999ZZ

Ingred Name:KEROSENE (PETROLEUM), HYDROTREATED; (REFINED PETROLEUM
    SOLVENTS)
CAS:64742-47-8
RTECS #:OA5504000
OSHA PEL:100 PPM (MFR)
ACGIH TLV:100 PPM (MFR)

Ingred Name:ETHANOL, 2-BUTOXY-; (ETHYLENE GLYCOL MONOBUTYL ETHER)
CAS:111-76-2
RTECS #:KJ8575000
Fraction by Wt: 2-6%
OSHA PEL:50 PPM, S
ACGIH TLV:25 PPM, S

Ingred Name:SUP DAT: (EXTRACTED FROM DHHS (NIOSH) PUBLICATION # 90-118)
    .
RTECS #:9999999ZZ

Ingred Name:FIRST AID PROC: IMMED MED ATTN. INGEST: DO NOT INDUCE VOMIT
    UNLESS DIRECTED BY MD. SEEK IMMED MED ADVICE &/ATTN.
RTECS #:9999999ZZ

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYES: MAY CAUSE IRRIT. DIRECT
    CONT W/LIQ/EXPOS TO ITS VAPS/MISTS MAY CAUSE BURNING,
    TEARING/REDNESS. SKIN: MAY CAUSE IRRIT. PRLNG/RPTD EXPOS MAY CAUSE
    REDNESS, BURNING, DRYING/CRACKING OF SKIN/ DERM. INHAL: INHAL OF
    EXCESS CONC OF VAPS/MISTS MAY CAUSE IRRIT OF NOSE & THROAT & SIGNS
    OF NERV SYS (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: DEPRESS (DROW, DIZZ, LOSS OF COORD &
    FATG). INGEST: INGEST OF EXCESS QTYS MAY CAUSE IRRIT OF DIGEST
    TRACT & SIGNS OF NERV SYS DEPRESS (DROW, DIZZ, LOSS OF COORD &
    FATG). ACUTE EXPOS TO THESE  CMPDS RSLT IN NARCOSIS, PULM EDEMA &
    SEV KIDNEY & LIVER DMG. ASPIR HAZ. THIS MATL CAN ENTER LUNGS DURING
    (SUP DAT)
Medical Cond Aggravated by Exposure:PERS W/PREEXISTING SKIN DISORDERS
    MAY BE MORE SUSCEPTIBLE TO THE EFTS OF THIS MATL. PERS W/IMPAIRED
    LUNG FUNCTION/ASTHMA-LIKE CNDTNS MAY EXPERIENCE ADDNL BRTHG DFCLTY
    DUE TO IRRIT PROPERTIES OF MATL.

=======================  First Aid Measures  =======================

First Aid:EYE: GENTLY FLUSH W/LGE QTYS OF WATER FOR AT LEAST 15 MIN. IF
    IRRIT PERSISTS, SEEK IMMED MED ATTN. SKIN: REMOVE CONTAM CLTHG.
    CLEANSE AFFECTED AREAS THORO BY WASHING W/MILD SOAP & WATER. IF
    IRRIT/REDN ESS DEVELOPS & PERSISTS, SEEK MED ATTN.INHAL: IF DFCLT
    BRTHG, DIZZ/LT HEAD OCCUR WHEN WORKING IN AREAS W/HIGH VAP CONCS,
    SEEK AIR FREE OF VAPS. IF BRTHG STOPS, BEGIN ARTF RESP & SEEK (ING
    4)

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:146F,63C
Lower Limits:1.2%
Upper Limits:6.0%
Extinguishing Media:SMALL FIRES: USE DRY CHEMICAL, CARBON DIOXIDE OR
    FOAM. LARGE FIRES: THE USE OF DRY CHEMICAL OR FOAM IS RECOMMENDED.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
    . WATER SPRAY MAY BE USEFUL IN MIN VAPS & COOLING CONTRS EXPOSED TO
    HEAT & FLAME. AVOID SPREADING (SUP DAT)
Unusual Fire/Explosion Hazard:THIS MATERIAL IS COMBUSTIBLE AND MAY BE
    IGNITED BY HEAT OR FLAME. THIS MATERIAL WILL BURN, BUT WILL NOT
    IGNITE READILY.

==================  Accidental Release Measures  ==================

Spill Release Procedures:STAY UPWIND AND AWAY FROM SPILL. KEEP ALL
    SOURCES OF IGNITION AND HOT METAL SURFACES AWAY FROM SPILL. IF
    SPILL IS INDOORS, VENTILATE AREA OF SPILL. FOAM, ESPECIALLY HIGH
    EXPANSION FOAM, MAY BE USED TO  SUPPRESS VAPORS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:KEEP CONTRS TIGHTLY CLOSED. KEEP
    CONTRS COOL, DRY, & AWAY FROM SOURCES OF IGNIT. USE & STORE THIS
    PROD W/ADEQUATE VENTILATION. AVOID INHAL OF VAPS.
Other Precautions:DO NOT PRESSURIZE, CUT, WELD, BRAZE, SOLDER, DRILL,
    GRIND/EXPOSE SUCH CONTRS TO HEAT, FLAME, SPARKS/OTHER SOURCES OF
    IGNIT. "EMPTY" DRUMS SHOULD BE COMPLETELY DRAINED, PROPERLY BUNGED
    & PROMPTLY SHIPP ED TO QUALIFIED DRUM RECONDITIONER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:RESP PROT MAY BE NECESSARY TO MINIMIZE EXPOS TO
    ORGANIC VAPORS/GASES. DEPENDING ON THE NATURE & CONCENTRATION OF
    THE AIRBORNE MATERIAL, USE RESPIRATOR/GAS MASK W/APPROPRIATE
    CARTRIDGES & CANISTERS (NI OSH/MSHA APPRVD)/SUPPLIED AIR EQUIP.
Ventilation:IF CURRENT VENTILATION PRACTICES ARE NOT ADEQUATE FOR
    MINIMIZING EXPOSURES, ADDITIONAL VENTILATION OR EXHAUST (ING 5)
Protective Gloves:IMPERMEABLE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGS .
Other Protective Equipment:EMERGENCY EYEWASH & DELUGE SHOWER MEETING
    ANSI DESIGN CRITERIA . IMPERVIOUS CLOTHING SHOULD BE WORN AS
    NEEDED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC: BURNING LIQ W/WATER USED FOR COOLING PURPOSES. EFTS OF
    OVEREXP: SWALLOWING/VOMIT & CAUSE LUNG INFLAMM & DMG. ANIMAL
    STUDIES CLEARLY DEMONSTRATED DOSE-RELATED ADVERSE EFTS ON CNS, HEMA
    TOPOIETIC TISS, BLOOD, KIDNEYS & LIVER,ASSOC W/ADMIN OF ETHYLENE
    GLYCOL MONOBUTYL ETHER (EGBE) (ING 3)

==================  Physical/Chemical Properties  ==================

Boiling Pt:B.P. Text:>370F,>188C
Vapor Pres:NEGLIGIBLE
Vapor Density:HVR/AIR
Spec Gravity:0.805 
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:LIGHT BLUE, WITH MILD CHARACTERISTIC ODOR
Percent Volatiles by Volume:100

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
THIS PRODUCT IS INCOMPATIBLE WITH STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:THERMAL DECOMPOSITION IN THE PRESENCE
    OF AIR MAY YIELD CARBON MONOXIDE AND/OR CARBON DIOXIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:KEEP CONTAINED AND DISPOSE OF IN ACCORDANCE WITH
    LOCAL, COUNTY, STATE, AND FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.